Unitech MS920 Manuel d'utilisateur Page 85

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 118
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 84
- 79 -
Aim
Scanning / Triggering
Triggering modes
Continuous
- At power up the lighting and decoding are on all the time. The trigger is not
used.
Continuous
Level (*)
- Lighting and decoding are on when the trigger line is activated (trigger
pressed) and off when the trigger line is deactivated (trigger released).
Level (*)
Pulse
- Lighting and decoding are on when the trigger line is activated (trigger
pressed) and stay on until a period of inactivity lasting the time specied by
the trigger timeout.
- After the timeout lighting and decoding are turned off.
Pulse
Flashing
- At power up the lighting and decoding are on (no need to activate the trigger
line) and after a period of inactivity lasting the time specied by the trigger
timeout, the scanner starts ashing, checking for a bar code to be read.
Vue de la page 84