Unitech MS920 Manuel d'utilisateur Page 73

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 118
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 72
- 67 -
Check digit transmission
[leading character] [number system] [data] [check digit]
Disable (*)
Enable
Unconventional stop
Disable (*)
Enable
Barcode length
- Use the L1 as minimum length option if you know the minimum length of the
codes in your application!!!
- To optimize decoding performance and increase security, select the same
length as the minimum length in your application (do not select a shorter
length!!).
Length = [start] + [barcode data] + [2-character check digit] + [stop]
- Minimum length possible = 5 characters.
Maximum length possible = 25 characters.
Length mode
- L1 = Codes with as many characters as specied by L1 and longer are read
(L2 and L3 are not used).
- L2 = Only codes that comply with the lengths specied by L1, L2, and L3 will
be read.
Vue de la page 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 117 118

Commentaires sur ces manuels

Pas de commentaire