Unitech MS100 Manuel d'utilisateur Page 26

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 59
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 25
22
MS100 Manual
Data Editing
Qualifier
The Qualifier section defines the conditions that must be present for
the bar code to be modified, such as what type of bar code it must be
(Code 39, EAN-13, etc.), what length the bar code must be, or what
characters (defined by a match string) the bar code must contain.
When the conditions of the Qualifier are met, the bar code is then
modified according to the rules defined in the “Modifier”, below.
From Original extracts the desired
data from the existing bar code.
The Start Parameter defines the
beginning of the string of data that
is to be output. The start parameter
can either be defined by position
starting from the beginning (“From
Position”), or a specific number of
characters from the end of the string (“From Last Position”), or a
specified number of characters before or after a user-defined char-
acter string (“After Matching”).
Modifier
The Modifier section contains three selections: “From Original”,
Add New”, and “Delete”.
The End Parameter defines the end of the string of data that is to
be output. Three options are available: “Number Of Characters To
Output”, “All Remaining”, and “After Matching”. The first two are
self-explanatory. “After Matching” defines the end as a specified
number of characters before or after a user-defined character string.
Data Editing is a powerful function that can give you tremendous
control over how data is exported from the scanner.
After clicking on “Data Editing” the
data editing icons become active.
Click on the icon with the blue
circle and white plus sign.
The “Define Formula” pop-up box to
the right appears, which is divided
into two sections: “Qualifier” and
“Modifier”.
Vue de la page 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 58 59

Commentaires sur ces manuels

Pas de commentaire